Blue Opal/Electrics: Difference between revisions
No edit summary |
|||
| (16 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
Blue Opal | === Battery banks === | ||
House bank - 2x 105 Ah SLA. Effective 100 Ah. | |||
Starter - 1x 80 Ah SLA. Effective 40 Ah. | |||
=== Alternator === | |||
BV PSH 80A, Hitachi saddle mount. Sourced from Myles Balfe. V-belt sheave. | |||
[[File:Img 2122-768x1024.jpg|none|thumb|Part number is 985.001.080.200.]] | |||
[[File:Alternator specifications for Blue Opal.jpg|none|thumb]] | |||
=== Terminal and driver sizes === | |||
{| class="wikitable" | |||
|+ | |||
!Area | |||
!Item | |||
!Fixing | |||
!Driver | |||
!Stud | |||
|- | |||
|Battery | |||
|Shunt | |||
|Terminal | |||
|10mm | |||
|8mm | |||
|- | |||
| | |||
|House | |||
|Terminal | |||
|14mm | |||
|10mm | |||
|- | |||
| | |||
|Starter | |||
|Terminal | |||
|13/14mm | |||
|10mm | |||
|- | |||
| | |||
|Blue Sea Fused Bus | |||
|Terminal | |||
|10mm | |||
|5mm | |||
|- | |||
| | |||
|MIDI fuses | |||
|Terminal | |||
|10mm | |||
|8mm | |||
|- | |||
| | |||
|Negative bus | |||
|Terminal | |||
|14mm | |||
|8mm | |||
|} | |||
=== Core power distribution and charging=== | |||
This diagram is for the wiring in the starter and house battery bank compartments. | |||
Charge and Distribution fuses are MIDI style with spare, Blue Sea 7720. | |||
Solar charger fuse is inline automotive, 5A to the local house bus positive. | |||
Solar feed is via a Bulgin Buccaneer connector that terminates to Anderson PowerPole, and solar panel has MC4 <-> MC4 <-> APP. | |||
2026-08: Update needed - Solar is MPPT 75/15, connected to bus bars that connect to the lithium house. Bus bar connects to battery +ve, to charge line from DC-DC, and feeds MPPT and Cerbo GX. Negative bus connects to starter negative, house negative, MPPT and Cerbo negative. Renogy replaced with 100W folding panel from Amazon. Feed line for solar in cockpit using Bulgin Buccaneer 10-250V, fed via ferruled wires to MPPT. | |||
{{#mermaid:config.theme = neutral | | |||
graph TD; | |||
subgraph "Lithium 180Ah (2024)" | |||
HOUSE_BAT_NEG[-]; | |||
HOUSE_BAT_POS[+]; | |||
end | |||
subgraph "Starter Battery (2023)" | |||
STARTER_BAT_POS[+]; | |||
STARTER_BAT_NEG[-]; | |||
end | |||
subgraph "House Battery Switch" | |||
HOUSE_SW_POS[S]; | |||
HOUSE_SW_LOAD[L]; | |||
end | |||
subgraph "Engine Battery Switch" | |||
ENG_SW_SOURCE[S]; | |||
ENG_SW_LOAD[L]; | |||
end | |||
subgraph "Alternator" | |||
ALT_GEN_POS[+]; | |||
end | |||
subgraph "BC1240 (Mains)" | |||
MAINS_CHG_ENG[Starter]; | |||
MAINS_CHG_HOU["Unused(House)"]; | |||
MAINS_CHG_NEG[-]; | |||
end | |||
subgraph "BB1240 (B2B 12V)" | |||
BB1240_STARTER[Source]; | |||
BB1240_NEG[Neg]; | |||
BB1240_HOU[Target]; | |||
end | |||
subgraph "Engine Panel" | |||
IGNITION([Ignition Switch]); | |||
end | |||
subgraph "House Shunt" | |||
HOUSE_SHUNT_POS[S] | |||
HOUSE_SHUNT_NEG[L] | |||
HOUSE_SHUNT_MON[Tap] | |||
HOUSE_SHUNT_POS --- HOUSE_SHUNT_NEG; | |||
HOUSE_SHUNT_POS --- HOUSE_SHUNT_MON --- HOUSE_SHUNT_NEG; | |||
end | |||
subgraph "House +ve Busbar" | |||
HOUSE_LBUS_POS[6x] | |||
end | |||
subgraph "House -ve Busbar" | |||
HOUSE_LBUS_NEG[6x] | |||
end | |||
subgraph "Solar" | |||
SOLAR_PANEL["100 Wp"] | |||
subgraph "MPPT75/15" | |||
SOLAR_IN_POS[S] | |||
SOLAR_IN_NEG[S] | |||
SOLAR_OUT_NEG[L] | |||
SOLAR_OUT_POS[L] | |||
end | end | ||
SOLAR_PANEL --- SOLAR_IN_POS; | |||
SOLAR_PANEL --- SOLAR_IN_NEG; | |||
end | |||
subgraph "Charge Fuse" | |||
STARTER_CHARGE_FUSE_SOURCE[S] | |||
STARTER_CHARGE_FUSE(70A) | |||
STARTER_CHARGE_FUSE_LOAD[L] | |||
STARTER_CHARGE_FUSE_SOURCE --- STARTER_CHARGE_FUSE --- STARTER_CHARGE_FUSE_LOAD; | |||
end | |||
BAT_NEG_BUS[Battery Negative Busbar]; | |||
BSA_STUD[BlueSea Ancillary] | |||
HOUSE_POS_BUS[House Positive Bus] | |||
HOUSE_NEG_BUS[House Negative Bus]; | |||
HOUSE_DIST_FUSE(Distribution Fuse 150A) | |||
HOUSE_CHARGE_FUSE(Charge Fuse 70A) | |||
GROUND[Engine Block]; | |||
WLS_SW_POS([Windlass Switch]); | |||
ALWAYS_ON_DIST[Always On Bus]; | |||
WINDLASS_NEG[Windlass]; | |||
HOUSE_LBUS_POS ==== HOUSE_DIST_FUSE; | |||
HOUSE_LBUS_NEG === STARTER_BAT_NEG; | |||
HOUSE_SW_POS --- ALWAYS_ON_DIST; | |||
FRIDGE[Chillbox] --- BAT_NEG_BUS; | |||
STARTER_CHARGE_FUSE_LOAD --- STARTER_BAT_POS; | |||
HOUSE_CHARGE_FUSE === HOUSE_LBUS_POS; | |||
STARTER_BAT_POS == 25mm ==> ENG_SW_SOURCE; | |||
STARTER_BAT_NEG === HOUSE_SHUNT_POS ; | |||
ENG_SW_LOAD --- IGNITION; | |||
ENG_SW_LOAD --- WLS_SW_POS; | |||
ALT_GEN_POS == 16mm ==> STARTER_CHARGE_FUSE_SOURCE; | |||
BB1240_NEG === STARTER_BAT_NEG; | |||
STARTER_CHARGE_FUSE_SOURCE == 10mm === BB1240_STARTER; | |||
BB1240_HOU == 10mm ==> HOUSE_CHARGE_FUSE; | |||
BAT_NEG_BUS === HOUSE_NEG_BUS; | |||
MAINS_CHG_NEG === BAT_NEG_BUS; | |||
HOUSE_SW_LOAD === HOUSE_POS_BUS; | |||
HOUSE_DIST_FUSE --- HOUSE_SW_POS; | |||
HOUSE_SW_LOAD === BSA_STUD; | |||
HOUSE_SHUNT_NEG === BAT_NEG_BUS; | |||
STARTER_BAT_NEG ==== GROUND; | |||
MAINS_CHG_ENG --- STARTER_CHARGE_FUSE_SOURCE; | |||
SOLAR_OUT_POS --- HOUSE_LBUS_POS; | |||
SOLAR_OUT_NEG --- HOUSE_LBUS_NEG; | |||
WINDLASS_NEG --- STARTER_BAT_NEG; | |||
HOUSE_LBUS_POS --- HOUSE_BAT_POS; | |||
HOUSE_LBUS_NEG --- HOUSE_BAT_NEG; | |||
classDef pos stroke:#f00 | |||
classDef fuse stroke:#00f,fill:#5c5; | |||
class HOUSE_BAT_POS,HOUSE_DIST_FUSE_POS,WLS_SW_POS,ENG_SW_SOURCE,ENG_SW_LOAD,HOUSE_SW_POS pos; | |||
class STARTER_CHARGE_FUSE_SOURCE,SOLAR_IN_POS,SOLAR_OUT_POS pos; | |||
class ENG_CHG_FUSE_POS,STERLING_STARTER,STERLING_HOUSE,IGNITION pos; | |||
class MAINS_CHG_HOU,MAINS_CHG_ENG,STARTER_BAT_POS,ALT_GEN_POS pos; | |||
class HOUSE_SW_LOAD pos; | |||
class STARTER_CHARGE_FUSE_LOAD pos; | |||
class BB1240_HOU,BB1240_STARTER pos; | |||
class ALWAYS_ON_DIST,BSA_STUD,HOUSE_POS_BUS pos; | |||
class HOUSE_DIST_FUSE,HOUSE_CHARGE_FUSE,STARTER_CHARGE_FUSE fuse; | |||
}} | |||
To-do: Replace direct-to-terminal with distribution bus bars. Starter negative terminal has more than 4 cables attached. | |||
=== Blue Sea Ancillary=== | |||
This distribution setup is used for power distribution in the saloon; it's in the same physical area as the batteries. Distributor is a Blue Sea Systems ST compact 8-circuit (5046) with 10-32 stud, and 8-32 screw terminals. | |||
{{#mermaid:graph LR; | |||
HOU_SWITCH["House Battery Switch (Load)"]; | |||
BAT_NEG_BUS[Battery Negative Busbar]; | |||
subgraph "BlueSea Ancillary" | |||
BSA_STUD(Stud); | |||
BSA_FRIDGE(Fridge 15); | |||
BSA_AMPS(Ammeter 3A); | |||
BSA_PP1(Powerpole 20A); | |||
BSA_PP2(Powerpole 20A); | |||
BSA_USB(USB 5A); | |||
BSA_BILGE(Bilge 5A); | |||
BSA_WPUMP(Water Pump 15A); | |||
BSA_STUD --- BSA_FRIDGE & BSA_AMPS & BSA_PP1 & BSA_PP2 & BSA_USB & BSA_BILGE & BSA_WPUMP; | |||
end | |||
HOU_SWITCH === BSA_STUD; | |||
BSA_FRIDGE === FRIDGE[Chillbox] === BAT_NEG_BUS; | |||
BSA_AMPS --- AMMETER[Ammeter] --- BAT_NEG_BUS; | |||
BSA_PP1 --- PP1[Powerpole] --- BAT_NEG_BUS; | |||
BSA_PP2 --- PP2[Powerpole] --- BAT_NEG_BUS; | |||
BSA_USB --- USB_SALOON[USB Sockets] --- BAT_NEG_BUS; | |||
BSA_BILGE --- BILGE[Bilge Pump] --- BAT_NEG_BUS; | |||
BSA_WPUMP --- WATER_PUMP[Fresh Water Pump] --- BAT_NEG_BUS; | |||
classDef pos stroke:#f00 | |||
classDef fuse stroke:#00f,fill:#5c5; | |||
class HOU_SWITCH pos; | |||
class BSA_FRIDGE,BSA_AMPS,BSA_PP1,BSA_PP2,BSA_USB,BSA_BILGE,BSA_WPUMP fuse; | |||
| | |||
config.theme = neutral | |||
}} | |||
=== Always on distribution === | |||
This powers low draw devices that should be powered without the house switch being engaged. Basically, lights. Located in the wiring cabinet above and behind the chart table. Wired to supply side so it's always got power, bar the local fuse blowing. | |||
{{#mermaid:graph LR; | |||
HOU_SWITCH("House Battery Switch (Supply)"); | |||
BAT_NEG_BUS[Battery Negative Busbar]; | |||
CAB_NEG_BUS[Wiring Cabinet -ve Bus] | |||
subgraph "BlueSea 4-fuse" | |||
BSA_STUD(Stud); | |||
BSA_SALOON(Saloon 3A); | |||
BSA_CHART(Chart Table 3A); | |||
BSA_CABINET(Cabinet 1A); | |||
BSA_STUD --- BSA_SALOON & BSA_CHART & BSA_CABINET; | |||
end | |||
HOU_SWITCH === BSA_STUD; | |||
BSA_SALOON --- SALOON_SW(Companionway Switch) --- SALOON[Saloon Light] --- CAB_NEG_BUS; | |||
BSA_CHART --- CHART_SW(Chart Table Switch) --- CHART_LIGHT[Chart Table Light] --- CAB_NEG_BUS; | |||
BSA_CABINET --- CABINET_SW(Wiring Cabinet Switch) --- CABINET_LIGHT[Cabinet Light] --- CAB_NEG_BUS; | |||
CAB_NEG_BUS === BAT_NEG_BUS; | |||
classDef pos stroke:#f00 | |||
classDef fuse stroke:#00f,fill:#5c5; | |||
class HOU_SWITCH pos; | |||
class BSA_SALOON,BSA_CHART,BSA_CABINET fuse; | |||
| | |||
config.theme = neutral | |||
}} | |||
=== Water pump === | |||
Wired via a relay so that the switch by the chart table just activates the relay, and the pump gets power from 6mm<sup>2</sup> direct from the battery compartment. | |||
{{#mermaid:graph LR; | |||
subgraph "Relay" | |||
SWITCHING_TERMINAL[Switching]; | |||
SWITCHED_TERMINAL[Switched]; | |||
end | |||
subgraph "Pump" | |||
PUMP_POS[+]; | |||
PUMP_NEG[-]; | |||
end | |||
BAT_NEG_BUS[Battery Negative Busbar]; | |||
CAB_NEG_BUS[Wiring Cabinet -ve Bus] | |||
PUMP_PANEL_SW(Panel Switch); | |||
BSA_BAT_PUMP(Blue Sea Ancillary); | |||
PUMP_PANEL_SW --> SWITCHING_TERMINAL --> CAB_NEG_BUS; | |||
BSA_BAT_PUMP --> SWITCHED_TERMINAL --> PUMP_POS; | |||
PUMP_NEG --> BAT_NEG_BUS; | |||
classDef pos stroke:#f00 | |||
classDef fuse stroke:#00f,fill:#5c5; | |||
class BSA_BAT_PUMP fuse; | |||
class PUMP_PANEL_SW pos; | |||
| | |||
config.theme = neutral | |||
}} | |||
The relay is the same as the one for the engine starter, 12V 40A SPST with 30/85/86/87 terminals, normally open. | |||
[[Category:Blue Opal]] | |||
Latest revision as of 20:11, 25 August 2026
Battery banks
House bank - 2x 105 Ah SLA. Effective 100 Ah. Starter - 1x 80 Ah SLA. Effective 40 Ah.
Alternator
BV PSH 80A, Hitachi saddle mount. Sourced from Myles Balfe. V-belt sheave.


Terminal and driver sizes
| Area | Item | Fixing | Driver | Stud |
|---|---|---|---|---|
| Battery | Shunt | Terminal | 10mm | 8mm |
| House | Terminal | 14mm | 10mm | |
| Starter | Terminal | 13/14mm | 10mm | |
| Blue Sea Fused Bus | Terminal | 10mm | 5mm | |
| MIDI fuses | Terminal | 10mm | 8mm | |
| Negative bus | Terminal | 14mm | 8mm |
Core power distribution and charging
This diagram is for the wiring in the starter and house battery bank compartments.
Charge and Distribution fuses are MIDI style with spare, Blue Sea 7720.
Solar charger fuse is inline automotive, 5A to the local house bus positive.
Solar feed is via a Bulgin Buccaneer connector that terminates to Anderson PowerPole, and solar panel has MC4 <-> MC4 <-> APP.
2026-08: Update needed - Solar is MPPT 75/15, connected to bus bars that connect to the lithium house. Bus bar connects to battery +ve, to charge line from DC-DC, and feeds MPPT and Cerbo GX. Negative bus connects to starter negative, house negative, MPPT and Cerbo negative. Renogy replaced with 100W folding panel from Amazon. Feed line for solar in cockpit using Bulgin Buccaneer 10-250V, fed via ferruled wires to MPPT.
To-do: Replace direct-to-terminal with distribution bus bars. Starter negative terminal has more than 4 cables attached.
Blue Sea Ancillary
This distribution setup is used for power distribution in the saloon; it's in the same physical area as the batteries. Distributor is a Blue Sea Systems ST compact 8-circuit (5046) with 10-32 stud, and 8-32 screw terminals.
Always on distribution
This powers low draw devices that should be powered without the house switch being engaged. Basically, lights. Located in the wiring cabinet above and behind the chart table. Wired to supply side so it's always got power, bar the local fuse blowing.
Water pump
Wired via a relay so that the switch by the chart table just activates the relay, and the pump gets power from 6mm2 direct from the battery compartment.
The relay is the same as the one for the engine starter, 12V 40A SPST with 30/85/86/87 terminals, normally open.