Blue Opal/Electrics: Difference between revisions
mNo edit summary |
|||
(5 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
=== Battery banks === | === Battery banks === | ||
House bank - 2x 105 Ah SLA. Effective 100 Ah. | House bank - 2x 105 Ah SLA. Effective 100 Ah. | ||
Starter - 1x | Starter - 1x 80 Ah SLA. Effective 40 Ah. | ||
Alternator | |||
BV PSH 80A, Hitachi saddle mount. Sourced from Myles Balfe. V-belt sheave. | |||
[[File:Img 2122-768x1024.jpg|none|thumb|Part number is 985.001.080.200.]] | |||
[[File:Alternator specifications for Blue Opal.jpg|none|thumb]] | |||
=== Terminal and driver sizes === | === Terminal and driver sizes === | ||
Line 57: | Line 63: | ||
{{#mermaid:config.theme = neutral | graph TD; | {{#mermaid:config.theme = neutral | graph TD; | ||
subgraph "House Battery 1" | subgraph "House Bank" | ||
subgraph "House Battery 1 (2019)" | |||
HOUSE_BAT1_NEG[-]; | |||
HOUSE_BAT1_POS[+]; | HOUSE_BAT1_POS[+]; | ||
end | end | ||
subgraph "House Battery 2" | subgraph "House Battery 2 (2019)" | ||
HOUSE_BAT2_NEG[-]; | |||
HOUSE_BAT2_POS[+]; | HOUSE_BAT2_POS[+]; | ||
end | end | ||
subgraph "Starter Battery" | end | ||
subgraph "Starter Battery (2023)" | |||
STARTER_BAT_POS[+]; | STARTER_BAT_POS[+]; | ||
STARTER_BAT_NEG[-]; | STARTER_BAT_NEG[-]; | ||
Line 72: | Line 80: | ||
subgraph "House Battery Switch" | subgraph "House Battery Switch" | ||
HOUSE_SW_POS[S]; | HOUSE_SW_POS[S]; | ||
HOUSE_SW_LOAD[L]; | |||
end | end | ||
subgraph "Engine Battery Switch" | subgraph "Engine Battery Switch" | ||
ENG_SW_SOURCE[S]; | |||
ENG_SW_LOAD[L]; | |||
end | end | ||
Line 82: | Line 90: | ||
ALT_GEN_POS[+]; | ALT_GEN_POS[+]; | ||
end | end | ||
subgraph "BC1240 (Mains)" | subgraph "BC1240 (Mains)" | ||
MAINS_CHG_ENG[Starter]; | |||
MAINS_CHG_HOU["Unused(House)"]; | |||
MAINS_CHG_NEG[-]; | MAINS_CHG_NEG[-]; | ||
end | end | ||
subgraph "BB1240 (12V)" | |||
subgraph "BB1240 (B2B 12V)" | |||
BB1240_STARTER[Source]; | BB1240_STARTER[Source]; | ||
BB1240_NEG[Neg]; | BB1240_NEG[Neg]; | ||
Line 101: | Line 111: | ||
HOUSE_SHUNT_NEG[L] | HOUSE_SHUNT_NEG[L] | ||
HOUSE_SHUNT_MON[Tap] | HOUSE_SHUNT_MON[Tap] | ||
HOUSE_SHUNT_POS -- | HOUSE_SHUNT_POS --- HOUSE_SHUNT_NEG; | ||
HOUSE_SHUNT_POS --- HOUSE_SHUNT_MON --- HOUSE_SHUNT_NEG; | HOUSE_SHUNT_POS --- HOUSE_SHUNT_MON --- HOUSE_SHUNT_NEG; | ||
end | |||
subgraph "Solar" | |||
SOLAR_PANEL["200 Wp Renogy"] | |||
subgraph "Votronic 250" | |||
SOLAR_IN_POS[S] | |||
SOLAR_IN_NEG[S] | |||
SOLAR_OUT_POS[L] | |||
SOLAR_OUT_NEG[L] | |||
end | |||
SOLAR_PANEL --- SOLAR_IN_POS; | |||
SOLAR_PANEL --- SOLAR_IN_NEG; | |||
end | |||
subgraph "Charge Fuse" | |||
STARTER_CHARGE_FUSE_SOURCE[S] | |||
STARTER_CHARGE_FUSE(70A) | |||
STARTER_CHARGE_FUSE_LOAD[L] | |||
STARTER_CHARGE_FUSE_SOURCE --- STARTER_CHARGE_FUSE --- STARTER_CHARGE_FUSE_LOAD; | |||
end | end | ||
Line 111: | Line 140: | ||
HOUSE_DIST_FUSE(Distribution Fuse 150A) | HOUSE_DIST_FUSE(Distribution Fuse 150A) | ||
HOUSE_CHARGE_FUSE(Charge Fuse 70A) | HOUSE_CHARGE_FUSE(Charge Fuse 70A) | ||
GROUND[Engine Block]; | GROUND[Engine Block]; | ||
WLS_SW_POS([Windlass Switch]); | WLS_SW_POS([Windlass Switch]); | ||
ALWAYS_ON_DIST[Always On Bus]; | ALWAYS_ON_DIST[Always On Bus]; | ||
WINDLASS_NEG[Windlass]; | |||
HOUSE_BAT2_POS === HOUSE_BAT1_POS; | |||
HOUSE_BAT2_NEG === HOUSE_BAT1_NEG; | |||
HOUSE_BAT1_POS ==== HOUSE_DIST_FUSE; | HOUSE_BAT1_POS ==== HOUSE_DIST_FUSE; | ||
HOUSE_BAT1_NEG === STARTER_BAT_NEG; | HOUSE_BAT1_NEG === STARTER_BAT_NEG; | ||
Line 123: | Line 152: | ||
HOUSE_SW_POS --- ALWAYS_ON_DIST; | HOUSE_SW_POS --- ALWAYS_ON_DIST; | ||
FRIDGE[Chillbox] --- BAT_NEG_BUS; | FRIDGE[Chillbox] --- BAT_NEG_BUS; | ||
STARTER_CHARGE_FUSE_LOAD --- STARTER_BAT_POS; | |||
HOUSE_CHARGE_FUSE -- | HOUSE_CHARGE_FUSE --- HOUSE_BAT1_POS; | ||
STARTER_BAT_POS | STARTER_BAT_POS == 25mm ==> ENG_SW_SOURCE; | ||
STARTER_BAT_NEG === HOUSE_SHUNT_POS ; | STARTER_BAT_NEG === HOUSE_SHUNT_POS ; | ||
ENG_SW_LOAD --- IGNITION; | |||
ENG_SW_LOAD --- WLS_SW_POS; | |||
ALT_GEN_POS == 16mm ==> | ALT_GEN_POS == 16mm ==> STARTER_CHARGE_FUSE_SOURCE; | ||
BB1240_NEG === STARTER_BAT_NEG; | BB1240_NEG === STARTER_BAT_NEG; | ||
STARTER_CHARGE_FUSE_SOURCE == 10mm === BB1240_STARTER; | |||
BB1240_HOU == 10mm ==> HOUSE_CHARGE_FUSE; | BB1240_HOU == 10mm ==> HOUSE_CHARGE_FUSE; | ||
BAT_NEG_BUS === HOUSE_NEG_BUS; | BAT_NEG_BUS === HOUSE_NEG_BUS; | ||
MAINS_CHG_NEG === BAT_NEG_BUS; | MAINS_CHG_NEG === BAT_NEG_BUS; | ||
HOUSE_SW_LOAD === HOUSE_POS_BUS; | |||
HOUSE_DIST_FUSE --- HOUSE_SW_POS; | HOUSE_DIST_FUSE --- HOUSE_SW_POS; | ||
HOUSE_SW_LOAD === BSA_STUD; | |||
HOUSE_SHUNT_NEG === BAT_NEG_BUS; | HOUSE_SHUNT_NEG === BAT_NEG_BUS; | ||
STARTER_BAT_NEG ==== GROUND; | STARTER_BAT_NEG ==== GROUND; | ||
MAINS_CHG_ENG -- | MAINS_CHG_ENG --- STARTER_CHARGE_FUSE_SOURCE; | ||
SOLAR_OUT_POS --- STARTER_BAT_POS; | |||
SOLAR_OUT_NEG --- STARTER_BAT_NEG; | |||
WINDLASS_NEG --- STARTER_BAT_NEG; | |||
classDef pos stroke:#f00 | classDef pos stroke:#f00 | ||
classDef fuse stroke:#00f,fill:#5c5; | classDef fuse stroke:#00f,fill:#5c5; | ||
class HOUSE_BAT1_POS,HOUSE_BAT2_POS,HOUSE_DIST_FUSE_POS, | class HOUSE_BAT1_POS,HOUSE_BAT2_POS,HOUSE_DIST_FUSE_POS,WLS_SW_POS,ENG_SW_SOURCE,ENG_SW_LOAD,HOUSE_SW_POS pos; | ||
class STARTER_CHARGE_FUSE_SOURCE,SOLAR_IN_POS,SOLAR_OUT_POS pos; | |||
class ENG_CHG_FUSE_POS,STERLING_STARTER,STERLING_HOUSE,IGNITION pos; | class ENG_CHG_FUSE_POS,STERLING_STARTER,STERLING_HOUSE,IGNITION pos; | ||
class MAINS_CHG_HOU,MAINS_CHG_ENG,STARTER_BAT_POS,ALT_GEN_POS pos; | class MAINS_CHG_HOU,MAINS_CHG_ENG,STARTER_BAT_POS,ALT_GEN_POS pos; | ||
class HOUSE_SW_LOAD pos; | |||
class STARTER_CHARGE_FUSE_LOAD pos; | |||
class BB1240_HOU,BB1240_STARTER pos; | class BB1240_HOU,BB1240_STARTER pos; | ||
class ALWAYS_ON_DIST,BSA_STUD,HOUSE_POS_BUS pos; | class ALWAYS_ON_DIST,BSA_STUD,HOUSE_POS_BUS pos; | ||
Line 152: | Line 187: | ||
}} | }}To-do: Replace direct-to-terminal with distribution bus bars. Starter negative terminal has more than 4 cables attached. | ||
=== Blue Sea Ancillary=== | === Blue Sea Ancillary=== |
Latest revision as of 11:29, 2 August 2024
Battery banks
House bank - 2x 105 Ah SLA. Effective 100 Ah. Starter - 1x 80 Ah SLA. Effective 40 Ah.
Alternator
BV PSH 80A, Hitachi saddle mount. Sourced from Myles Balfe. V-belt sheave.
Terminal and driver sizes
Area | Item | Fixing | Driver | Stud |
---|---|---|---|---|
Battery | Shunt | Terminal | 10mm | 8mm |
House | Terminal | 14mm | 10mm | |
Starter | Terminal | 13/14mm | 10mm | |
Blue Sea Fused Bus | Terminal | 10mm | 5mm | |
MIDI fuses | Terminal | 10mm | 8mm | |
Negative bus | Terminal | 14mm | 8mm |
Core power distribution and charging
This diagram is for the wiring in the starter and house battery bank compartments.
Charge and Distribution fuses are MIDI style with spare, Blue Sea 7720.
Solar charger fuse is inline automotive.
To-do: Replace direct-to-terminal with distribution bus bars. Starter negative terminal has more than 4 cables attached.
Blue Sea Ancillary
This distribution setup is used for power distribution in the saloon; it's in the same physical area as the batteries. Distributor is a Blue Sea Systems ST compact 8-circuit (5046) with 10-32 stud, and 8-32 screw terminals.
Always on distribution
This powers low draw devices that should be powered without the house switch being engaged. Basically, lights. Located in the wiring cabinet above and behind the chart table. Wired to supply side so it's always got power, bar the local fuse blowing.
Water pump
Wired via a relay so that the switch by the chart table just activates the relay, and the pump gets power from 6mm2 direct from the battery compartment.
The relay is the same as the one for the engine starter, 12V 40A SPST with 30/85/86/87 terminals, normally open.